- Spi Digital Protractor User Manual Digital Level, 360 Protractor and Inclinometer. Calibration services for SPI tronic instruments including, SPI tronic PRO 360 - digital protractor. PDF DOWNLOAD SIEMENS AQUASTOP USER MANUAL SQL TUNING EBOOK DOWNLOAD. Recent SPI 0715' Grad 00001 Spi Dial Bore Gauge questions, problems & answers.
- 9040 Introduction The Fluke 9040 Phase Rotation Indicator (the 9040) is a handheld instrument designed to detect the rotary field of three-phase systems. How to Contact Fluke To contact Fluke, call one of the following telephone numbers:. Technical Support USA: 1.
- This instrument is a bench-top optical device incorporating a projection screen with a protractor readout calibrated in two-degree increments. The image can be independently adjusted along both the horizontal and vertical axis and focused on the screen with an axial micrometer adjustment. A precision micrometer.
- Empire 598 Troubador owners manual, service manuals and schematics are for reference only and the Vinyl Engine bears no responsibility for errors or other inaccuracies. The PDF files are provided under strict licence. Reproduction without prior.
#071
TO FIND YOUR POSITION:
Drafting Machine Controls and Machine Head Operation 5 FIGURE 4. Angle measurements with either a horizontal or a vertical reference line. To measure full-degree increments, match the zero mark on the vernier plate with a full-degree mark on the protractor. See the reading of 12° in Figure 5. The vernier scale allows you to. VITEK® 2 Instrument User Manual i 510731-10EN1 GENERAL WARNINGS IMPORTANT: The user is advised to read and understand all instructions in this manual to be able to derive the best performance from the VITEK® 2 instrument and the Smart Carrier Station. IMPORTANT: The configuration that you have purchased is adapted to the legislation. Protractor, One-Arm Instructions, A. Protractor, One-Arm Instructions. Download Direct Link. Version: A File Name: 0631ArmProINST.PDF Released: May 01, 2015.
1) Select three features that are clearly recognizable
on your chart—for example, a lighthouse, a small
harbor, and a church steeple.
2) Using your hand bearing compass, pelorus, or
sextant, take the bearings of each of the three fea-
tures. Calculate the number of degrees from the
central feature to the feature on the right, and from
the central feature to the feature on the left.
3) Using the stationary arm of the protractor to repre-
sent the central feature and the two rotating arms
to represent the features on either side, set the
arms to the degrees calculated in Step #2 above.
To set degrees, place the long black line of each
rotating arm over the nearest whole degree mark
on the protractor scale. To set minutes, rotate the
arm slightly until the desired number of minutes on
the vernier scale (the scale on the rotating arm)
lines up exactly with a degree mark on the protrac-
tor scale.
4) Without changing the setting of the arms, manipu-
late the protractor on the chart until the long black
line on each arm is over the corresponding land
feature.
Union Instrument Corp Protractor User Manual Pdf Download
5) Mark your position through the center hole of the
protractor.
THREE-ARM PROTRACTOR
INSTRUCTIONS
Note: This product was discontinued in 2003.
3465 Diablo Ave., Hayward, CA 94545 U.S.A.
Phone (510) 732-9229 • Fax (510) 732-9188
Union Instrument Corp Protractor User Manual Pdf 2 8
info@davisnet.com www.davisnet.com
071_Inst.pdf October 2005